Page 11
Installation Manual Pyramid Universal Dome Interface
CONNECTING A MARK MERCER DOME CAMERA
To connect a Mark Mercer dome camera to the UDI, follow the steps below:
When connecting the UDI to a dome, reference should also be made to documentation provided with the dome.
1. Remove the top panel from the dome camera housing. The connections are made inside this top panel.
2. Inside the top panel, locate the twelve-way terminal block to which power, video, alarm and network connections
are made. Connect the wire from the UDIs Dome Data Connector to the terminals marked RS485A and RS485B
as shown below:
WIRES FROM DOME DATA CONNECTOR ON UDI:
FROM GROUND TERMINAL
FROM - TERMINAL
FROM + TERMINAL
Connecting a Mark Mercer Dome to the UDI
3. Inside the top panel, there are three rotary switches. These rotary switches are labelled S1, S2 and S3, and they
should be used to set the dome address to 1. To do this, set the first rotary switch (S3) to 0, the second rotary switch
(S2) to 0 and the third rotary switch (S1) to 1 as shown below:
Configuring an Mark Mercer Dome
4. Refit the top panel to the dome camera housing.
CONNECTING A JVC DOME CAMERA
To connect a JVC dome camera to the UDI, follow the steps below:
When connecting the UDI to a dome, reference should also be made to documentation provided with the dome.
1. Locate the data connector on the top of the dome. The connector is slightly different for TK-C675 and TK-C676
models as shown below.
2. Connect the wire from the UDIs Dome Data Connector to the terminals marked Rx+ and Rx- as shown in the
diagram below. There is no need to connect the terminals marked Tx+ and Tx- as the dome is to operate in
simplex mode.
FROM + TERMINAL
FROM - TERMINAL
WIRES FROM DOME DATA CONNECTOR ON UDI
FROM - TERMINAL
FROM + TERMINAL
K-C675
ODEL
TK-C676
MODEL
Connecting a JVC Dome to the UDI